Curing Tank Temperature Controller Automatic
Curing Tank Temperature Controller for Concrete Cubes
NABL Calibrated | Single & Three Phase | Waterproof & Shockproof | Heater, Chiller & Pump Ready
Vedantrik Technologies presents an advanced curing tank temperature controller designed specifically for concrete cube curing tanks used in NABL-accredited laboratories, RMC plants, construction site labs, and infrastructure projects.
The system accurately maintains the standard curing temperature of 27 ± 2 °C, as prescribed by IS and NABL guidelines. Equipped with an intelligent temperature controller, SS316 waterproof immersion heaters, and built-in electrical safety protections, this solution eliminates manual temperature monitoring and ensures consistent, audit-compliant curing conditions.
Each system can be supplied with an NABL-traceable calibration certificate, making it suitable for laboratory audits and quality assurance processes.
Concrete Curing Tank Temperature Control System
This plug-and-play curing tank controller manages heating during winter and cooling during summer, ensuring uninterrupted and uniform curing of concrete test specimens.
The controller supports both single phase and three phase power supplies, allowing it to work seamlessly with different tank sizes and heater configurations without any modification.
Ideal Applications
- Concrete cube curing tanks
- NABL civil engineering laboratories
- Construction site testing laboratories
- RMC plants and QA/QC departments
- Infrastructure and government projects
Technical Specifications – Curing Tank Controller
- Power Supply: Single Phase / Three Phase AC, 230 V
- Maximum Current Capacity: 32 Amps
- Temperature Set Point: 27 ± 2 °C
- Temperature Accuracy: ±1 °C
- Controller Power Cord Length: 2 meters
- Temperature Sensor Cable Length: 5 meters
Plug & Play Connections
- Heater connection
- Chiller connection
- Water circulation pump connection
- Temperature sensor connection
- No skilled installation required.
Key Features of Curing Tank Temperature Controller
- Compatible with single phase and three phase heaters
- Dedicated socket for chiller (summer curing)
- Dedicated socket for circulation pump
- Built-in short circuit and over-current protection
- Integrated MCB and RCCB for complete electrical safety
- Rugged design suitable for laboratory and onsite conditions
Smart Heating & Cooling Logic (Energy Efficient)
Heating Control – Winter Operation
- Heater switches OFF above 27 °C
- Heater switches ON below 25 °C
- Prevents overheating and reduces power consumption
Chiller Control – Summer Operation
- Chiller switches ON above 29 °C
- Chiller switches OFF below 25 °C
- Maintains curing temperature as per NABL and IS standards
Heater Selection Based on Curing Tank Volume
- Below 2000 liters: Single phase heater recommended
- Above 2000 liters: Three phase heater recommended
- The controller supports both heater types without any modification.
Electrical Load Capacity of Controller
Three Phase Heater Load
- Heater Rating: 4 kW per unit
- Minimum Load: 1 × 4 kW
- Maximum Load: 4 × 4 kW (Total 16 kW)
Single Phase Heater Load
- Heater Rating: Up to 2 kW per unit
- Minimum Load: 1 heater
- Maximum Load: 4 × 4 kW (Total 16 kW)
Note:
Single phase heaters draw higher current; therefore, lower total power is recommended. For large curing tanks, three phase heaters provide better efficiency and stability.
SS316 Waterproof & Shockproof Immersion Heaters
Three Phase Immersion Heater
- Power Rating: 4 kW
- Cable Length: 5 meters
- Cable Type: 5-core
- Heater Material: SS316
- Protection: Waterproof & shockproof
Single Phase Immersion Heater
- Power Rating: 2 kW
- Cable Length: 5 meters
- Cable Type: 3-core
- Heater Material: SS316
- Protection: Waterproof & shockproof
Recommended Heater Configuration for Curing Tanks
Single Phase System (Small & Medium Tanks)
- 2000 liters: 1 × 2 kW heater
- 4000 liters: 2 × 2 kW heaters
- 6000 liters: 3 × 2 kW heaters
- Maintains 27 ± 2 °C curing temperature.
Three Phase System (Large Tanks)
- Up to 2500 liters: 1 × 4 kW heater
- Up to 5000 liters: 2 × 4 kW heaters (8 kW)
- Up to 7500 liters: 3 × 4 kW heaters (12 kW)
- Up to 10,000 liters: 4 × 4 kW heaters (16 kW)
Best Practices for Uniform Concrete Curing
- Interconnect multiple curing tanks using a water circulation pump
- For identical tanks in the same environment, one temperature sensor is sufficient
- For different tank sizes, place the sensor in the largest tank
- Use multiple controllers for independent temperature control
- Multichannel curing tank controller available for economical multi-tank operation
NABL Compliance & Custom Solutions
- NABL-traceable temperature calibration certificate available
- Multichannel and customized curing tank controllers
- Designed for NABL labs, RMC plants, infrastructure projects, and site laboratories
Contact for Pricing & Technical Support
Topic covered above
- Curing tank temperature controller
- Concrete cube curing tank controller
- NABL curing tank temperature controller
- Concrete curing tank heater
- SS316 immersion heater for curing tank
- Single phase curing tank heater
- Three phase curing tank heater
- Concrete laboratory curing equipment
- Curing tank temperature control system
